RELIABLE, HIGH-QUALITY MONOFOCAL VISION

Designed to reduce chromatic aberration and produce long-term performance, the SENSAR® IOL can help you give your patients the reliable, quality vision associated with our monofocal IOLs.   

HIGH-QUALITY LENS DESIGN

The SENSAR® IOL offers the high-quality lens design, materials and optics that can be expected from Abbott intraocular lenses.

  • Hydrophobic material is not associated with glistenings1
  • ProTEC 360° edge design helps limit LEC migration
  • Lower Abbe number compared to competing acrylic IOLs2
  • Reduces the transmission of UV light while still allowing healthy blue light, which has proven to be essential for maintaining optimal scotopic vision3

SENSAR® 1-Piece IOL

OPTIC CHARACTERISTICS

Powers:

+6.0 D to 30.0 D in 0.5 diopter increments

Diameter:

6.0 mm

Material:

UV-blocking hydrophobic acrylic

Refractive Index:

1.47 at 35˚ C

Edge Design:

ProTEC frosted, continuous 360˚ posterior square edge

ULTRASOUND BIOMETRY*

A-Constant:

118.4

Theoretical AC Depth:

5.2 mm

Surgeon Factor:

1.45 mm

HAPTIC CHARACTERISTICS

Overall Length:

13.0 mm

Style:

C

Material:

UV-blocking hydrophobic acrylic

Design:

Haptics offset from optic

CONTACT

Contact a representative

RESOURCES

Directions for Use
(PDF, 12.8 MB)

FOOTNOTES

*Value theoretically derived for a typical 20.0 D lens. AMO recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model, and postoperative results.

REFERENCES

  1. Data On File, Abbott Medical Optics Inc., 2013.
  2. Zhao H, Mainster MA. The effect of chromatic dispersion on pseudophakic optical performance. Br J Ophthalmol. 2007;91(9):1225-1229.
  3. Mainster MA. Violet and blue-light blocking intraocular lenses: Photoprotection versus photoreception. Br J Ophthalmol. 2006;90:784-792.

INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR THE SENSAR® MONOFOCAL 1-PIECE IOL

Rx Only

INDICATIONS

SENSAR® 1-Piece Lenses are indicated for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction. These devices are intended to be placed in the capsular bag.

PRECAUTIONS

Do not resterilize the lens. Most sterilizers are not equipped to sterilize the soft acrylic material without producing undesirable side effects. Do not reuse lens. Do not soak or rinse the intraocular lens with any solution other than sterile balanced salt solution or sterile normal saline. Do not store the lens in direct sunlight or at a temperature greater than 113°F (45°C). Do not autoclave the intraocular lens. Please refer to the specific instructions for use provided with the insertion instrument or system for the amount of time the IOL can remain folded before the IOL must be discarded. When the insertion system is used improperly, the haptics of the SENSAR® 1-Piece Lens may become damaged.

WARNINGS

Physicians considering lens implantation under any of the following circumstances should weigh the potential risk/benefit ratio: patients with recurrent severe anterior or posterior segment inflammation or uveitis, patients in whom the intraocular lens may affect the ability to observe, diagnose or treat posterior segment diseases, surgical difficulties at the time of cataract extraction, which may increase the potential for complications (e.g., persistent bleeding, significant iris damage, uncontrolled positive pressure or significant vitreous prolapse or loss), a compromised eye due to previous trauma or developmental defect in which appropriate support of the IOL is not possible, circumstances that would result in damage to the endothelium during implantation, suspected microbial infection, and patients in whom neither the posterior capsule nor the zonules are intact enough to provide support for the IOL. Children under the age of 2 years are not suitable candidates for intraocular lenses. AMO IOLs are single-use medical devices that are labeled with instructions for use and handling to minimize exposure to conditions that may compromise the product, patient, or the user. The reuse/resterilization/reprocessing of AMO single-use medical devices may result in physical damage to the medical device, failure of the medical device to perform as intended, and patient illness or injury due to infection, inflammation, and/ or illness due to product contamination, transmission of infection, and lack of product sterility. The SENSAR® 1-Piece IOL should be placed entirely in the capsular bag. Do not place the lens in the ciliary sulcus.

ADVERSE EVENTS

The most frequently reported cumulative adverse event that occurred during the clinical trial of the lens was cystoid macular edema, which occurred at a rate of 3.3%. Other reported adverse events include lens exchange and secondary surgical intervention, which occurred at a rate of 0.8%.

ATTENTION

Reference the labeling for a complete listing of Important Indications and Safety Information.

PP2016MLT0281

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. All other trademarks are the intellectual property of their respective owners.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

true
accessibility
© 2017 Abbott Laboratories Inc. Abbott Park, Illinois, USA. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company. All other trademarks are the intellectual property of their respective owners.

YESNO
accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. All other trademarks are the intellectual property of their respective owners.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

YESNO