Now FDA-approved, the TECNIS Symfony® and TECNIS Symfony® Toric IOLs help you leave a legacy of seamless brilliance for your patients.


LEAVE A LEGACY OF VISUAL FREEDOM

Your patients’ vision is only as good as the IOL you leave behind, so go beyond satisfaction and choose a lens to match each patient’s individual lifestyle.


TECNIS SYMFONY® IOL

Life happens at more than one distance, so give your patients the ability to live their lives in continuous clarity. Give them seamless, continuous vision while simultaneously mitigating the effects of presbyopia with TECNIS Symfony® Extended Depth of Focus IOLs.

  • Clear, continuous vision — near, far and in between1
  • Excellent uncorrected visual acuity with excellent image contrast1
  • High-quality vision in the presence of astigmatism2
  • Excellent performance in any lighting condition1
  • Low incidence of visual disturbances1

TECNIS SYMFONY® TORIC IOL

Give your patients the brilliant, continuous vision provided by the TECNIS Symfony® IOL with added astigmatism correction.


TECNIS® MULTIFOCAL 1-PIECE IOLs

No two patients are exactly alike, but with TECNIS® Multifocal IOLs, you can deliver spectacle independence where each patient needs it most. Our portfolio of lenses delivers a full range of the sharpest vision, enhanced functionality and long-term sustainability with tailored clarity to match their daily lifestyles.

TECNIS® Multifocal IOL +2.75 D

  • Tailored for intermediate-vision activities
  • Activities: Golfing, grocery shopping
  • Theoretical Reading Distance: 50 cm

TECNIS® Multifocal IOL +3.25 D

  • Tailored for longer reading-distance activities
  • Activities: Multimedia work
  • Theoretical Reading Distance: 42 cm

TECNIS® Multifocal IOL +4.0 D

  • Tailored for near-vision activities 
  • Activities: Reading, fine detail work
  • Theoretical Reading Distance: 33 cm

REFERENCES

  1. TECNIS Symfony® Extended Range of Vision IOLs DFU. Santa Ana, Calif. Abbott Medical Optics Inc.
  2. Data on File. Abbott Medical Optics Inc. 2016.

INDICATIONS AND IMPORTANT SAFETY INFORMATION

Rx Only

TECNIS SYMFONY® IOLs
INDICATIONS

The TECNIS Symfony® Extended Range of Vision IOL, model ZXR00, is indicated for primary implantation for the visual correction of aphakia, in adult patients with less than 1.0 diopter of pre-existing corneal astigmatism, in whom a cataractous lens has been removed. The lens mitigates the effects of presbyopia by providing an extended depth of focus. Compared to an aspheric monofocal IOL, the lens provides improved intermediate and near visual acuity while maintaining comparable distance visual acuity. The model ZXR00 IOL is intended for capsular bag placement only. The TECNIS Symfony® Toric Extended Range of Vision IOLs, models ZXT150, ZXT225, ZXT300, and ZXT375, are indicated for primary implantation for the visual correction of aphakia and for reduction of residual refractive astigmatism in adult patients with greater than or equal to 1 diopter of preoperative corneal astigmatism, in whom a cataractous lens has been removed. The lens mitigates the effects of presbyopia by providing an extended depth of focus. Compared to an aspheric monofocal IOL, the lens provides improved intermediate and near visual acuity, while maintaining comparable distance visual acuity. The model series ZXT IOLs are intended for capsular bag placement only.

WARNINGS

Physicians considering lens implantation under any of the following circumstances should weigh the potential risk/benefit ratio. Patients with any of the following conditions may not be suitable candidates for an intraocular lens because the lens may exacerbate an existing condition, may interfere with diagnosis or treatment of a condition, or may pose an unreasonable risk to the patient’s eyesight:  patients with recurrent severe anterior or posterior segment inflammation or uveitis of unknown etiology, or any disease producing an inflammatory reaction in the eye, patients in whom the intraocular lens may affect the ability to observe, diagnose or treat posterior segment diseases, surgical difficulties at the time of cataract extraction, which may increase the potential for complications (e.g., persistent bleeding, significant iris damage, uncontrolled positive pressure or significant vitreous prolapse or loss), a compromised eye due to previous trauma or developmental defects in which appropriate support of the IOL is not possible, circumstances that would result in damage to the endothelium during implantation, suspected microbial infection, patients in whom neither the posterior capsule nor the zonules are intact enough to provide support for the IOL, children under the age of 2 years are not suitable candidates for intraocular lenses, congenital bilateral cataracts, previous history of, or a predisposition to, retinal detachment, patients with only one good eye with potentially good vision, medically uncontrollable glaucoma, corneal endothelial dystrophy or proliferative diabetic retinopathy. The TECNIS Symfony® IOL should be placed entirely in the capsular bag and should not be placed in the ciliary sulcus. The TECNIS Symfony® IOL may cause a reduction in contrast sensitivity under certain conditions, compared to an aspheric monofocal IOL. The physician should carefully weigh the potential risks and benefits for each patient, and should fully inform the patient of the potential for reduced contrast sensitivity before implanting the lens in patients. Special consideration of potential visual problems should be made before implanting the lens in patients with macular disease, amblyopia, corneal irregularities, or other ocular disease which may cause present or future reduction in acuity or contrast sensitivity. Because the TECNIS Symfony® IOL may cause a reduction in contrast sensitivity compared to a monofocal IOL, patients implanted with the lens should be informed to exercise special caution when driving at night or in poor visibility conditions. Some visual effects associated with the TECNIS Symfony® IOL may be expected due to the lens design that delivers elongation of focus. These may include a perception of halos, glare, or starbursts around lights under nighttime conditions. The experience of these phenomena will be bothersome or very bothersome in some people, particularly in low-illumination conditions. On rare occasions, these visual effects may be significant enough that the patient may request removal of the IOL. Patients with a predicted postoperative astigmatism greater than 1.0 diopter may not be suitable candidates for implantation with the TECNIS Symfony® and TECNIS Symfony® Toric IOLs, models ZXR00, ZXT150, ZXT225, ZXT300, and ZXT375, as they may not obtain the benefits of reduced spectacle wear or improved intermediate and near vision seen in patients with lower astigmatism. The effectiveness of TECNIS Symfony® Toric IOLs in reducing postoperative residual astigmatism in patients with preoperative corneal astigmatism < 1.0 diopter has not been demonstrated. Rotation of TECNIS Symfony® Toric IOLs away from their intended axis can reduce their astigmatic correction. Misalignment greater than 30° may increase postoperative refractive cylinder. If necessary, lens repositioning should occur as early as possible prior to lens encapsulation. AMO IOLs are single-use devices only. Do not reuse this IOL.

PRECAUTIONS

Prior to surgery, the surgeon must inform prospective patients of the possible risks and benefits associated with the use of this device and provide a copy of the patient information brochure to the patient. When performing refraction in patients implanted with the TECNIS Symfony® IOL, interpret results with caution when using autorefractors or wavefront aberrometers that utilize infrared light, or when performing a duochrome test. Confirmation of refraction with maximum plus manifest refraction technique is recommended. The ability to perform some eye treatments (e.g. retinal photocoagulation) may be affected by the TECNIS Symfony® IOL optical design. Recent contact lens usage may affect the patient’s refraction; therefore, in contact lens wearers, surgeons should establish corneal stability without contact lenses prior to determining IOL power.  Do not resterilize the lens. Most sterilizers are not equipped to sterilize the soft acrylic material without producing undesirable side effects. Do not soak or rinse the intraocular lens with any solution other than sterile balanced salt solution or sterile normal saline. Do not store the lens in direct sunlight or at a temperature greater than 113°F (45°C). Do not autoclave the intraocular lens. The surgeon should target emmetropia as this lens is designed for optimum visual performance when emmetropia is achieved. Care should be taken to achieve IOL centration, as lens decentration may result in a patient experiencing visual disturbances under certain lighting conditions. When the insertion system is used improperly, TECNIS Symfony® IOLs may not be delivered properly (i.e., haptics may be broken). Please refer to the specific instructions for use provided with the insertion instrument or system. The safety and effectiveness of TECNIS Symfony® IOLs have not been substantiated in patients with preexisting ocular conditions and intraoperative complications (see below for examples). Careful preoperative evaluation and sound clinical judgment should be used by the surgeon to decide the benefit/risk ratio before implanting a lens in a patient with one or more of these conditions: [before surgery] pupil abnormalities, prior corneal refractive or intraocular surgery, choroidal hemorrhage, chronic severe uveitis, concomitant severe eye disease, extremely shallow anterior chamber, medically uncontrolled glaucoma, microphthalmos, non-age-related cataract, proliferative diabetic retinopathy (severe), severe corneal dystrophy, severe optic nerve atrophy, irregular corneal astigmatism, amblyopia, macular disease, pregnancy, [during surgery] excessive vitreous loss, non-circular capsulotomy/capsulorhexis, the presence of radial tears known or suspected at the time of surgery, situations in which the integrity of the circular capsulotomy/capsulorhexis cannot be confirmed by direct visualization, cataract extraction by techniques other than phacoemulsification or liquefaction, capsular rupture, significant anterior chamber hyphema, uncontrollable positive intraocular pressure, or zonular damage. Carefully remove all viscoelastic and do not over-inflate the capsular bag at the end of the case. Residual viscoelastic and/or overinflation of the capsular bag may allow the lens to rotate, causing misalignment of the TECNIS Symfony® Toric IOL with the intended axis of placement. The use of methods other than the TECNIS Toric Calculator to select cylinder power and appropriate axis of implantation were not assessed in the parent TECNIS® Toric IOL U.S. IDE study and may not yield similar results. Accurate keratometry and biometry, in addition to the use of the TECNIS Toric Calculator (www.TecnisToricCalc.com), are recommended to achieve optimal visual outcomes for the TECNIS Symfony® Toric IOL. All preoperative surgical parameters are important when choosing a TECNIS Symfony® Toric IOL for implantation, including preoperative keratometric cylinder (magnitude and axis), incision location, surgeon’s estimated surgically induced astigmatism (SIA) and biometry. The PCA is based on an algorithm that combines published literature (Koch et.al, 2012) and a retrospective analysis of data from a TECNIS® Toric multi-center clinical study. The PCA algorithm for the selection of appropriate cylinder power and axis of implantation was not assessed in a prospective clinical study and may yield results different from those in the TECNIS® Toric intraocular lens labeling. Please refer to the AMO Toric Calculator use manual for more information. Variability in any of the preoperative measurements can influence patient outcomes, and the effectiveness of treating eyes with lower amounts of preoperative corneal astigmatism. All corneal incisions were placed temporally in the parent TECNIS® Toric IOL U.S. IDE study. If the surgeon chooses to place the incision at a different location, outcomes may be different from those obtained in the clinical study for the parent Tecnis Toric IOL. Note that the TECNIS Toric Calculator incorporates the surgeon’s estimated SIA and incision location when providing IOL options. Potential adverse effects (e.g., complications) associated with the use of the device include the following: infection (endophthalmitis), hypopyon, iol dislocation, cystoid macular edema, corneal edema, pupillary block, iritis, retinal detachment/tear, raised iop requiring treatment visual symptoms requiring lens removal, tilt and decentration requiring repositioning, and residual refractive error resulting in secondary intervention. Secondary surgical interventions include, but are not limited to: lens repositioning (due to decentration, rotation, subluxation, etc.), lens replacement, vitreous aspirations or iridectomy for pupillary block, wound leak repair, retinal detachment repair, corneal transplant, lens replacement due to refractive error, unacceptable optical/visual symptoms and severe inflammation.

SERIOUS ADVERSE EVENTS

The most frequently reported serious adverse events that occurred during the clinical trial of the TECNIS Symfony® Lens were cystoid macular edema (2 eyes, 0.7%) and surgical reintervention (treatment injections for cystoid macular edema and endophthalmitis, 2 eyes, 0.7%). One eye was reported with pupillary capture and the eye that had endophthalmitis also had a small hypopyon. No other serious adverse events and no lens-related adverse events occurred during the trial.

TECNIS® MULTIFOCAL 1-PIECE IOLs
INDICATIONS

The TECNIS® Multifocal 1-Piece intraocular lenses are indicated for primary implantation for the visual correction of aphakia in adult patients with and without presbyopia in whom a cataractous lens has been removed by phacoemulsification and who desire near, intermediate, and distance vision with increased spectacle independence. The intraocular lenses are intended to be placed in the capsular bag.

WARNINGS

Physicians considering lens implantation under any of the conditions described in the Directions for Use should weigh the potential risk/benefit ratio prior to implanting a lens. Some visual effects associated with multifocal IOLs may be expected because of the superposition of focused and unfocused images. These may include a perception of halos/glare around lights under nighttime conditions. It is expected that, in a small percentage of patients, the observation of such phenomena will be annoying and may be perceived as a hindrance, particularly in low illumination conditions. On rare occasions, these visual effects may be significant enough that the patient will request removal of the multifocal IOL. Contrast sensitivity is reduced with a multifocal lens compared to a monofocal lens. Therefore, patients with multifocal lenses should exercise caution when driving at night or in poor visibility conditions. Patients with a predicted postoperative astigmatism >1.0D may not be suitable candidates for multifocal IOL implantation since they may not fully benefit from a multifocal IOL in terms of potential spectacle independence. Care should be taken to achieve centration, as lens decentration may result in patients experiencing visual disturbances, particularly in patients with large pupils under mesopic conditions. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Patients with certain medical conditions may not be suitable candidates for IOLs. Consult the Directions for Use for more information.

PRECAUTIONS

Prior to surgery, the surgeon must inform prospective patients of the possible risks and benefits associated with the use of this device and provide a copy of the patient information brochure to patient. There were no patients 21 years old or younger included in the clinical studies; therefore there are insufficient clinical data to demonstrate safety and effectiveness in this age group. The central one millimeter area of the lens creates a far image focus, therefore patients with abnormally small pupils (~1mm) should achieve, at a minimum, the prescribed distance vision under photopic conditions; however, because this multifocal design has not been tested in patients with abnormally small pupils, it is unclear whether such patients will derive any near vision benefit. Autorefractors may not provide optimal postoperative refraction of multifocal patients; manual refraction is strongly recommended. In contact lens wearers, surgeons should establish corneal stability without contact lenses prior to determining IOL power. Care should be taken when performing wavefront measurements as two different wavefronts are produced (one will be in focus (either far or near) and the other wavefront will be out of focus); therefore incorrect interpretation of the wavefront measurements is possible. The long-term effects of intraocular lens implantation have not been determined; therefore implant patients should be monitored postoperatively on a regular basis. Secondary glaucoma has been reported occasionally in patients with controlled glaucoma who received lens implants. The intraocular pressure of implant patients with glaucoma should be carefully monitored postoperatively. Do not resterilize or autoclave. Use only sterile irrigating solutions such as balanced salt solution or sterile normal saline. Do not store in direct sunlight or over 45°C (113°). Emmetropia should be targeted as this lens is designed for optimum visual performance when emmetropia is achieved. Please refer to the specific instructions for use provided with the insertion instrument or system for the amount of time the IOL can remain folded before the IOL must be discarded. When the insertion system is used improperly, the haptics of the IOL may become broken. Please refer to the specific instructions for use provided with the insertion instrument or system.

ADVERSE EVENTS

The most frequently reported adverse event that occurred during the clinical trials of the TECNIS® Multifocal lenses was surgical re-intervention, most of which were non-lens-related. Lens-related re-interventions occurred at a rate of 0.6% to 1.0%. Other surgical re-interventions included lens exchanges (for incorrect IOL power), retinal repair, ruptured globe repair, macular hole repair, removal of retained lens material, treatment injections for cystoid macular edema and iritis, and blepharoplasty.

ATTENTION

Reference the Directions for Use for a complete listing of Indications and Important Safety Information.

PP2016MLT0281

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. All other trademarks are the intellectual property of their respective owners.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

true
accessibility
© 2017 Abbott Laboratories Inc. Abbott Park, Illinois, USA. All Rights Reserved. Please read the Legal Notice for further details.

Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company. All other trademarks are the intellectual property of their respective owners.

YESNO
accessibility

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. All other trademarks are the intellectual property of their respective owners.


The website that you have requested also may not be optimized for your screen size.

Do you wish to continue and exit this website?

YESNO